001package org.hl7.fhir.r4.model.codesystems; 002 003/* 004 Copyright (c) 2011+, HL7, Inc. 005 All rights reserved. 006 007 Redistribution and use in source and binary forms, with or without modification, 008 are permitted provided that the following conditions are met: 009 010 * Redistributions of source code must retain the above copyright notice, this 011 list of conditions and the following disclaimer. 012 * Redistributions in binary form must reproduce the above copyright notice, 013 this list of conditions and the following disclaimer in the documentation 014 and/or other materials provided with the distribution. 015 * Neither the name of HL7 nor the names of its contributors may be used to 016 endorse or promote products derived from this software without specific 017 prior written permission. 018 019 THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND 020 ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 021 WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. 022 IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, 023 INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT 024 NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR 025 PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, 026 WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) 027 ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE 028 POSSIBILITY OF SUCH DAMAGE. 029 030*/ 031 032// Generated on Wed, Jan 30, 2019 16:19-0500 for FHIR v4.0.0 033 034import org.hl7.fhir.exceptions.FHIRException; 035 036public enum MetricOperationalStatus { 037 038 /** 039 * The DeviceMetric is operating and will generate DeviceObservations. 040 */ 041 ON, 042 /** 043 * The DeviceMetric is not operating. 044 */ 045 OFF, 046 /** 047 * The DeviceMetric is operating, but will not generate any DeviceObservations. 048 */ 049 STANDBY, 050 /** 051 * The DeviceMetric was entered in error. 052 */ 053 ENTEREDINERROR, 054 /** 055 * added to help the parsers 056 */ 057 NULL; 058 059 public static MetricOperationalStatus fromCode(String codeString) throws FHIRException { 060 if (codeString == null || "".equals(codeString)) 061 return null; 062 if ("on".equals(codeString)) 063 return ON; 064 if ("off".equals(codeString)) 065 return OFF; 066 if ("standby".equals(codeString)) 067 return STANDBY; 068 if ("entered-in-error".equals(codeString)) 069 return ENTEREDINERROR; 070 throw new FHIRException("Unknown MetricOperationalStatus code '" + codeString + "'"); 071 } 072 073 public String toCode() { 074 switch (this) { 075 case ON: 076 return "on"; 077 case OFF: 078 return "off"; 079 case STANDBY: 080 return "standby"; 081 case ENTEREDINERROR: 082 return "entered-in-error"; 083 case NULL: 084 return null; 085 default: 086 return "?"; 087 } 088 } 089 090 public String getSystem() { 091 return "http://hl7.org/fhir/metric-operational-status"; 092 } 093 094 public String getDefinition() { 095 switch (this) { 096 case ON: 097 return "The DeviceMetric is operating and will generate DeviceObservations."; 098 case OFF: 099 return "The DeviceMetric is not operating."; 100 case STANDBY: 101 return "The DeviceMetric is operating, but will not generate any DeviceObservations."; 102 case ENTEREDINERROR: 103 return "The DeviceMetric was entered in error."; 104 case NULL: 105 return null; 106 default: 107 return "?"; 108 } 109 } 110 111 public String getDisplay() { 112 switch (this) { 113 case ON: 114 return "On"; 115 case OFF: 116 return "Off"; 117 case STANDBY: 118 return "Standby"; 119 case ENTEREDINERROR: 120 return "Entered In Error"; 121 case NULL: 122 return null; 123 default: 124 return "?"; 125 } 126 } 127 128}