001package org.hl7.fhir.r4.model.codesystems;
002
003/*
004  Copyright (c) 2011+, HL7, Inc.
005  All rights reserved.
006  
007  Redistribution and use in source and binary forms, with or without modification, 
008  are permitted provided that the following conditions are met:
009  
010   * Redistributions of source code must retain the above copyright notice, this 
011     list of conditions and the following disclaimer.
012   * Redistributions in binary form must reproduce the above copyright notice, 
013     this list of conditions and the following disclaimer in the documentation 
014     and/or other materials provided with the distribution.
015   * Neither the name of HL7 nor the names of its contributors may be used to 
016     endorse or promote products derived from this software without specific 
017     prior written permission.
018  
019  THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND 
020  ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED 
021  WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. 
022  IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, 
023  INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT 
024  NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR 
025  PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, 
026  WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) 
027  ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE 
028  POSSIBILITY OF SUCH DAMAGE.
029  
030*/
031
032// Generated on Wed, Jan 30, 2019 16:19-0500 for FHIR v4.0.0
033
034import org.hl7.fhir.exceptions.FHIRException;
035
036public enum RejectionCriteria {
037
038  /**
039   * blood specimen hemolized.
040   */
041  HEMOLIZED,
042  /**
043   * insufficient quantity of specimen.
044   */
045  INSUFFICIENT,
046  /**
047   * specimen container broken.
048   */
049  BROKEN,
050  /**
051   * specimen clotted.
052   */
053  CLOTTED,
054  /**
055   * specimen temperature inappropriate.
056   */
057  WRONGTEMPERATURE,
058  /**
059   * added to help the parsers
060   */
061  NULL;
062
063  public static RejectionCriteria fromCode(String codeString) throws FHIRException {
064    if (codeString == null || "".equals(codeString))
065      return null;
066    if ("hemolized".equals(codeString))
067      return HEMOLIZED;
068    if ("insufficient".equals(codeString))
069      return INSUFFICIENT;
070    if ("broken".equals(codeString))
071      return BROKEN;
072    if ("clotted".equals(codeString))
073      return CLOTTED;
074    if ("wrong-temperature".equals(codeString))
075      return WRONGTEMPERATURE;
076    throw new FHIRException("Unknown RejectionCriteria code '" + codeString + "'");
077  }
078
079  public String toCode() {
080    switch (this) {
081    case HEMOLIZED:
082      return "hemolized";
083    case INSUFFICIENT:
084      return "insufficient";
085    case BROKEN:
086      return "broken";
087    case CLOTTED:
088      return "clotted";
089    case WRONGTEMPERATURE:
090      return "wrong-temperature";
091    case NULL:
092      return null;
093    default:
094      return "?";
095    }
096  }
097
098  public String getSystem() {
099    return "http://terminology.hl7.org/CodeSystem/rejection-criteria";
100  }
101
102  public String getDefinition() {
103    switch (this) {
104    case HEMOLIZED:
105      return "blood specimen hemolized.";
106    case INSUFFICIENT:
107      return "insufficient quantity of specimen.";
108    case BROKEN:
109      return "specimen container broken.";
110    case CLOTTED:
111      return "specimen clotted.";
112    case WRONGTEMPERATURE:
113      return "specimen temperature inappropriate.";
114    case NULL:
115      return null;
116    default:
117      return "?";
118    }
119  }
120
121  public String getDisplay() {
122    switch (this) {
123    case HEMOLIZED:
124      return "hemolized specimen";
125    case INSUFFICIENT:
126      return "insufficient specimen volume";
127    case BROKEN:
128      return "broken specimen container";
129    case CLOTTED:
130      return "specimen clotted";
131    case WRONGTEMPERATURE:
132      return "specimen temperature inappropriate";
133    case NULL:
134      return null;
135    default:
136      return "?";
137    }
138  }
139
140}